Elitech LD-200 Heated Diode HVAC Refrigerant Leak Detector AC Sniffer Rechargeable

  • High-precision Heated Diode Sensor: It triggers on R11/R22/R404a/R410a/R600a/R1234yf and all halogenated refrigerants including CFCs, HFCs, HCFCs, HCs, HFOs and blends.
  • 4 Simple Buttons: It allows to fast reset, mute, power on/off, adjust sensitivity and makes LED screen visually display the leakage level and device status.
  • Fast Response: Warms up in the 30s and respond in 3s; 6-grade adjustable sensitivity with maximum sensitivity 0.11oz/yr.
  • High Efficiency: Built-in air pump makes faster reaction and recovery speed possible and ensures detection efficiency.
  • Safe and Reliable: Meets EN14624 and SAE-1627 industrial standards.

Elitech LD-200 Heated Diode HVAC Refrigerant Leak Detector is among the existing portable refrigerant leak detector that offers the greatest sensitivity and fastest response.

LD-200 AC sniffer is achieved through the employment of a high sensitive heated diode sensor (semi-conductive sensor) combined with a sophisticated microprocessor-controlled circuit.

In addition to the supreme performance and functional advantages, it offers a unique designed shape to provide greater ease of use and comfort.

Upgraded Heated Diode Sensor

It adopts an upgraded heated diode sensor. Compared to the traditional corona sensor, it is more sensitive and less susceptible to false positives from other gases.

Multi-Functional Buttons

Four buttons: Reset, Mute, Power on/off, Sensitivity Preheating time: 30s  Response time: 3s  Audible and visual alarm View device status and leakage level form LED screen anytime

6 Adjustable Sensitivity

1-6 Grade selectable sensitivity.  Maximum sensitivity is 0.11oz/yr.  smaller leak, higher sensitivity grade.  More refrigerants, more rapidly beeps, faster indicator flashes

Gas leak detector is used to detect a gas leak or other emissions and can interface with a control system so a process can be automatically shut down.

A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave.

This type of device is important because there are many gases that can be harmful to organic life, such as humans or animals.

It will respond to all halogenated (including Chlorime of Fluorine) refrigerants.This includes, but it is not limited to:

  • CFCs e.g.R12, R11, R500, R503 etc.
  • HCFCs e.g. R22,R123, R124,R502 etc.
  • HFCs e.g. R134a, R404a, R410A, R407C etc.
  • CH e.g. R600a